Size: 2364
Comment:
|
Size: 2394
Comment: converted to 1.6 markup
|
| Deletions are marked like this. | Additions are marked like this. |
| Line 1: | Line 1: |
| attachment:mrclogo.gif | {{attachment:mrclogo.gif}} |
| Line 5: | Line 5: |
| Below you will find a short description of [#Magsgrads magnetometers and gradiometers], as well as our [#MEGsensors MEG sensor] and [#EEGlabels EEG electrode] layouts. | Below you will find a short description of [[#Magsgrads|magnetometers and gradiometers]], as well as our [[#MEGsensors|MEG sensor]] and [[#EEGlabels|EEG electrode]] layouts. |
| Line 7: | Line 7: |
| The [#Elektamanuals Elekta manuals] are at the bottom. | The [[#Elektamanuals|Elekta manuals]] are at the bottom. |
| Line 9: | Line 9: |
| Figures are from the Elekta Neuromag System [attachment:HardwareUser.pdf Hardware User's Manual]. | Figures are from the Elekta Neuromag System [[attachment:HardwareUser.pdf|Hardware User's Manual]]. |
| Line 15: | Line 15: |
| [[Anchor(Magsgrads)]] attachment:MagsGrads.jpg |
<<Anchor(Magsgrads)>> {{attachment:MagsGrads.jpg}} |
| Line 22: | Line 22: |
| [[Anchor(MEGsensors)]] attachment:SensorLayout.jpg |
<<Anchor(MEGsensors)>> {{attachment:SensorLayout.jpg}} |
| Line 25: | Line 25: |
| attachment:SensorLabeling.jpg | {{attachment:SensorLabeling.jpg}} |
| Line 29: | Line 29: |
| [[Anchor(EEGlabels)]] attachment:ElectrodeLayout.jpg |
<<Anchor(EEGlabels)>> {{attachment:ElectrodeLayout.jpg}} |
| Line 33: | Line 33: |
| [[Anchor(Elektamanuals)]] | <<Anchor(Elektamanuals)>> |
| Line 35: | Line 35: |
| [attachment:HardwareTechnical.pdf Hardware Technical Manual] | [[attachment:HardwareTechnical.pdf|Hardware Technical Manual]] |
| Line 37: | Line 37: |
| [attachment:HardwareUser.pdf Hardware User's Manual] | [[attachment:HardwareUser.pdf|Hardware User's Manual]] |
| Line 39: | Line 39: |
| [attachment:DataAcquisition.pdf Data Acquisition Manual] | [[attachment:DataAcquisition.pdf|Data Acquisition Manual]] |
| Line 41: | Line 41: |
| [attachment:StimulusSystem.pdf Stimulus System Manual] | [[attachment:StimulusSystem.pdf|Stimulus System Manual]] |
| Line 43: | Line 43: |
| [attachment:SensorTuner.pdf Sensor Tuner Manual] | [[attachment:SensorTuner.pdf|Sensor Tuner Manual]] |
| Line 45: | Line 45: |
| [wiki:CbuMeg:StandardOperatingProcedures Standard Operating Procedures] | [[StandardOperatingProcedures|Standard Operating Procedures]] |
The Elekta Neuromag Vectorview System
Below you will find a short description of magnetometers and gradiometers, as well as our MEG sensor and EEG electrode layouts.
The Elekta manuals are at the bottom.
Figures are from the Elekta Neuromag System Hardware User's Manual.
Technical description
Our Vectorview systems contains 102 magnetometers and 204 planar gradiometers. Magnetometers consist of a single coil which measures the magnetic flux perpendicular to its surface. Planar gradiometers consist of a "figure-of-eight"-type coil configuration. The measured signal is the difference between the two loops of the "eight", or the spatial gradient. There are two orthogonal planar gradiometers at each location. This arrangement is illustrated in the following figure (black: magnetometer; grey and white: two gradiometers).
It has been shown that 3 sensors of these types at one location measure independent information (their "leadfields" are orthogonal). It is therefore more efficient than placing 3 sensors of the same type (e.g. magnetometers) close to each other (they would basically measure the same signal 3 times). Our sensor configuration therefore provides an optimal sampling of the magnetic field for a given number of sensors. The downside is that magnetometers and gradiometers often have to be treated differently during analysis or visualisation.
This is the whole sensor layout, including the sensor labels used by the Neuromag software:
We routinely use a 70-electrode EEG set-up (Easycap) in combination with our MEG recordings. This is the electrode layout:
Elekta Manuals